Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.506
Filtrar
1.
J Esthet Restor Dent ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38665052

RESUMO

OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 106 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured. RESULTS: The failure-related survival rate (100%) and maximum fracture resistance of the MZrB were significantly higher than those of MC and Zr (50%; p < 0.05). There were no significant differences in the failure rate and fracture resistance when a CoCr base abutment was used or not in the translucent monolithic Zr groups (p > 0.05;MZrB vs. MZr). Failure location, with MC crowns' fractures, noted at the screw area (p = 0.043), while all-ceramic crowns were mostly in the cuspid and to failure area, the Zr group had the largest mean (15.55 ± 9.17 mm2) among the groups, significant difference only when compared with MC (1.62 ± 0.81 mm2) (p = 0.025). CONCLUSIONS: Translucent monolithic zirconia crowns exhibited significantly higher fatigue and fracture resistance compared with conventional MC and bilayered crowns. CLINICAL SIGNIFICANCE: The appropriate choice of material and manufacturing technique is crucial for predicting the higher clinical performance of single crowns. Enhanced mechanical resistance in terms of fatigue and fracture resistance can be achieved by replacing MC and bilayered restorations with computer-aided design and computer-aided manufacturing monolithic zirconia.

2.
J Prosthodont ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38666691

RESUMO

PURPOSE: This systematic review aims to compare clinical outcomes of digital dentures with conventional dentures. MATERIALS AND METHODS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in Prospero. The formulated population, intervention, comparison, outcome (PICO) question was "What is the clinical outcome of digital versus conventional complete dentures (CDs) in edentulous patients?". The search strategy used three main electronic databases and an additional manual search was completed in August 2023 by following an established search strategy. Initial inclusion was based on titles and abstracts, followed by a detailed review of selected studies, and clinical studies that evaluated the clinical outcome of digital (milled or 3D-printed) versus conventional CDs were included. A qualitative analysis for clinical studies was used to assess the risk of bias. The certainty of the evidence was assessed according to the grading of recommendations, assessment, development, and evaluations (GRADE) system. In addition, a single-arm meta-analysis was performed to evaluate the retention between digital versus conventional CDs. RESULTS: The initial search yielded a total of 947 articles, out of which 19 were selected for a comprehensive review, and six met the eligibility criteria to be included in this systematic review. The computer-aided design and computer-aided manufacturing (CAD-CAM) CDs showed increased retention, no relevant differences in oral health-related quality of life (OHRQoL), and shorter working time compared to conventional dentures. Two studies were eligible for meta-analysis; retention was significantly better among CAD-CAM fabricated dentures (standardized mean difference [SMD] 0.501) than conventional dentures. The heterogeneity between studies was high (95% CI: 0.049-0.952). CONCLUSIONS: Clinically, both the milled and the 3D-printed CD fared better than conventional dentures in terms of retention, reduction in the number of appointments, improved patient comfort, and improved predictable maintenance of the denture. Patients' perceptions and satisfaction were independent of the digital and conventional fabricated dentures.

3.
Dent J (Basel) ; 12(4)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38668006

RESUMO

The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies. To determine implant position, the generated STL files were imported into the Exocad CAD software and superimposed-automatically and manually-with the scanbody geometries stored within the software's shape library. Position accuracy was determined by a comparison of the 3D-defined scanbody points from the STL matching files with those from the reference STL files. The R statistical software was used for the evaluation of the data. In addition, mixed linear models and a significance level of 0.05 were applied to calculate the p-values. The manual overlay method was significantly more accurate than the automatic overlays for both scanbody types. The Medentika scanbodies showed slightly superior precision compared to the NT-Trading scanbodies. Both scanbody geometry and the type of alignment in the CAD software significantly affect digital workflow accuracy. Manual verification and adjustment of the automatic alignment process are essential for precise implant positioning.

4.
Nanomaterials (Basel) ; 14(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38668159

RESUMO

This study aimed to evaluate and compare the impact of additives such as ZrO2 and SiO2 nanoparticles (ZrO2NP or SiO2NP) on the hardness, surface roughness, and color stability of 3D printed provisional restorations. Two hundred samples in total were printed using 3D printed resins (ASIGA, and NextDent). Each resin was modified with ZrO2NPs or SiO2NPs in two different concentrations (0.5 wt% and 1 wt%), while one group was kept unmodified (n = 10). Disc-shaped (15 × 2.5 mm) samples were designed and printed in accordance with the manufacturer's recommendation. Printed discs were evaluated for color changes through parameters CIELAB 2000 system (ΔE00), hardness using Vickers hardness test, and surface roughness (Ra) using a noncontact profilometer. After calculating the means and standard deviations, a three-way ANOVA and Tukey post hoc test were performed at α = 0.05. The addition of ZrO2NPs or SiO2NPs to ASIGA and NextDent resins significantly increased the hardness at a given level of concentration (0.5% or 1%) in comparison with pure (p < 0.001), with no significant difference between the two modified groups per resin type (p > 0.05). The highest hardness value was detected in 1% ZrO2NPs with 29.67 ± 2.3. The addition of ZrO2NPs or SiO2NPs had no effect on the Ra (p > 0.05), with 1% ZrO2NPs showing the highest value 0.36 ± 0.04 µm with NextDent resin. ZrO2NPs induced higher color changes (∆E00), ranging from 4.1 to 5.8, while SiO2NPs showed lower values, ranging from 1.01 to 1.85, and the highest mean ∆E00 was observed in the 1% ZrO2NPs group and NextDent resin. The incorporation of ZrO2NPs and SiO2NPs in 3D printed provisional resins increased the hardness without affecting the surface roughness. The optical parameters were significantly affected by ZrO2NPs and less adversely affected by SiO2NPs. Consequently, care must be taken to choose a concentration that will improve the materials' mechanical performance without detracting from their esthetic value.

5.
J Prosthodont ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38638109

RESUMO

PURPOSE: Dental ceramics deteriorate as a result of thermal aging and exposure to acidic solutions, which change their microhardness and surface roughness. This study assessed the resistance of several computer-aided design and computer-aided manufacturing (CAD-CAM) restorative dental materials in terms of surface roughness and microhardness following exposure to acidic solutions and thermal aging. MATERIALS AND METHODS: Five different monolithic CAD-CAM restorative materials, two leucite-reinforced glass ceramics (G-Ceram and CEREC Blocs), a zirconia-infiltrated lithium silicate (Celtra Duo), a resin nanoceramic (Grandio), and monolithic zirconia (inCoris TZI), were used to create 2-mm-thick rectangular specimens (n = 100). After being immersed in either acidic saliva (pH = 4.0) (ST) or gastric juice (pH = 1.2) (GT), each material was subjected to 10,000 cycles of thermal aging. The Vickers microhardness and average surface roughness of the specimens were assessed at baseline, following thermal aging and exposure to either gastric juice or acidic saliva. The surface properties were examined using an atomic force microscope. The Mann‒Whitney U test with Bonferroni correction and the Wilcoxon signed-rank test was used for statistical analysis (a = 0.05). RESULTS: The surface roughness of two leucite-reinforced glass ceramics (G-ceram and CEREC) significantly decreased with ST (p = 0.027 and p = 0.044). Only the CEREC was affected when the aging protocols were compared, and the ST group had a significant reduction in roughness (p = 0.009). The microhardness values significantly decreased after both aging protocols in all groups except for the ST subgroup of G-Ceram. Only inCoris was affected when the aging protocols were compared, and the GT group exhibited a significant reduction in microhardness (p = 0.002). CONCLUSION: The surface roughness of the tested materials was not affected by the GT. Only leucite ceramics exhibited a decrease in surface roughness in the ST stage. Both aging processes produced a significant decrease in the microhardness of the tested ceramics. Leucite-reinforced glass-ceramic materials may be advantageous for patients with gastroesophageal reflux disease and those with a diet high in acidic foods due to their lower values for changes in microhardness and surface roughness compared to those of other CAD-CAM materials.

6.
Dent Mater J ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644215

RESUMO

This study aimed to evaluate the effects of different resin-coating technique strategies and dual-cure resin luting materials on proximal marginal adaptation and the microtensile bond strengths (µTBSs) of CAD/CAM hybrid ceramic inlays. Extracted human molars were classified into four groups, depending on the coating technique: No coating (None), single coating (1-coating), double coating (2-coating), and flowable resin-coating (Combination). The inlays were bonded with one of the three materials: Panavia V5 (V5), Rely X Ultimate (RXU), and Calibra Ceram (CC). The differences with regard to adaptation were not significant. In the case of µTBS data for V5, no significant differences were observed, whereas for RXU, µTBS values for Combination statistically exceeded those for None and 1-coating. For CC, µTBS values for Combination statistically exceeded those for None, 1-coating, and 2-coating. The coating techniques did not influence the adaptation but influenced the bond strength, and Combination performed the best.

7.
J Prosthodont Res ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644230

RESUMO

PURPOSE: The purpose of this study is to compare the shear bond strength of ultraviolet (UV)-polymerized resin to 3D-printed denture materials, both with and without post-polymerization. Moreover, the effects of surface treatment and thermocycling on shear bond strength after post-polymerization were investigated. METHODS: Cylindrical 3D-printed denture bases and teeth specimens were prepared. The specimens are subjected to two tests. For Test 1, the specimens were bonded without any surface treatment or thermal stress for comparison with and without post-polymerization. In Test 2, specimens underwent five surface treatments: untreated (CON), ethyl acetate (EA), airborne particle abrasion (APA) with 50 µm (50-APA) and 110 µm alumina (110-APA), and tribochemical silica coating (TSC). A UV-polymerized resin was used for bonding. Half of the Test 2 specimens were thermocycled for 10,000 cycles. Shear bond strength was measured and analyzed using Kruskal-Wallis and Steel-Dwass tests (n = 8). RESULTS: In Test 1, post-polymerization significantly reduced shear bond strength of both 3D-printed denture materials (P < 0.05). No notable difference was observed between the denture teeth and the bases (P > 0.05). In Test 2, before thermocycling, the CON and EA groups exhibited low bond strengths, while the 50-APA, 110-APA, and TSC groups exhibited higher bond strengths. Thermocycling did not reduce bond strength in the latter groups, but significantly reduced bond strength in the EA group (P < 0.001). CONCLUSIONS: Post-polymerization can significantly reduce the shear bond strength of 3D-printed denture materials. Surface treatments, particularly APA and TSC, maintained bond strength even after thermocycling.

8.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598918

RESUMO

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Assuntos
Óxido de Alumínio , Cerâmica , Teste de Materiais , Óxido de Alumínio/química , Cerâmica/química , Propriedades de Superfície , Zircônio/química , Desenho Assistido por Computador , Materiais Dentários
9.
Cureus ; 16(3): e55394, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38562321

RESUMO

In the field of removable prosthodontics, computer-aided design and computer-aided manufacturing (CAD/CAM) have become widely recognized. The traditional method, which uses heat-polymerized resins for injection or compression molding, necessitates up to five patient visits and laborious laboratory processes. A digital workflow combined with a CAD/CAM methodology can provide prompt prosthesis delivery for patients with time constraints. This article's goal is to outline the steps and the limitations in the fabrication of digital dentures as well as the challenges, limitations, and solutions developed while developing a clinical workflow for the rehabilitation of completely edentulous patients with the CAD/CAM System.

10.
J Prosthodont ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566330

RESUMO

Squamous cell carcinoma is a common malignant condition affecting the oral cavity and may involve the surrounding maxillofacial regions. Treatment commonly involves resection of the tumor, followed by prosthetic rehabilitation of the resection defect. This clinical report presents a 62-year-old Asian male patient who had previously undergone surgical resection, resulting in a post-surgical Aramany Class II maxillary defect. The patient's medical history included severe trismus, characterized by restricted mouth opening, as well as a diagnosis of maxillary sinus verrucous squamous cell carcinoma. This report provides a comprehensive account of the rapid fabrication of an interim obturator using digitally assisted dentistry techniques.

11.
J Prosthodont ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38566576

RESUMO

The purpose of this technical report is to demonstrate a fully digital workflow for designing and fabricating metal frameworks and removable partial dentures. After obtaining a digital cast of the dental arch with bilateral distal extension defect, computer-aided design software and 3D printing technology are used for the design and fabrication of the removable partial denture frameworks, denture teeth, and denture bases, instead of the traditional workflow. The assembly of the three components is facilitated through a meticulously structured framework. The technology, which prints metal frameworks, denture bases, and denture teeth through different processes with different materials, achieves full 3D printing technology for making removable partial dentures.

12.
J Surg Case Rep ; 2024(4): rjae202, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38577268

RESUMO

This report describes the bone reduction guide which was digitally obtained to improve diagnosis, treatment outcome and follow-up. Treatment of gingival smiles due to altered passive eruption should include interdisciplinary planning and smile design to facilitate the prediction of treatment outcome. Crown lengthening surgery can be supported by digital tools to improve surgical planning and follow-up. A 30-year-old female patient was referred to a private dental clinic seeking solutions for her gingival smile. Based on the anatomical crown length, a smile design was created, and the patient was presented with a simulated smile before treatment. In the surgical phase, a full-thickness flap was raised in the upper jaw to achieve the desired outcome. Using cone-beam computed tomography to determine cementoenamel junction for smile design and treatment planning brings many benefits. Patients and clinicians can foresee treatment results. From there, appropriate changes can be made. The bone reduction guide is designed to rest on the bone to help the clinician cut the bone accurately and thoroughly follow the established plan.

13.
J Mech Behav Biomed Mater ; 155: 106557, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38657286

RESUMO

The aim of this in vitro study was to evaluate the effect of the combinations of two different intraoral scanners (IOS), two milling machines, and two restorative materials on the marginal/internal fit and fatigue behavior of endocrowns produced by CAD-CAM. Eight groups (n= 10) were considered through the combination of TRIOS 3 (TR) or Primescan (PS) IOS; 4-axes (CR; CEREC MC XL) or 5-axes (PM; PrograMill PM7) milling machines; and lithium disilicate (LD; IPS e.max CAD) or resin composite (RC; Tetric CAD) restorative materials. Specific surface treatments were applied to each material, and the bonding to its corresponding Endocrown-shaped fiberglass-reinforced epoxy resin preparations was performed (Variolink Esthetic DC). Computed microtomography (µCT) was performed to assess the marginal/internal fit, as well as a mechanical fatigue test (20 Hz, initial load = 100 N/5000 cycles; step-size = 50 N/10,000 cycles until a threshold of 1500 N, then, the step-size was increased if needed to 100 N/10,000 cycles until failure or a threshold of 2800 N) to evaluate the restorations long-term behavior. Complementary analysis of the fracture features and surface topography in scanning electron microscopy was performed. Three-way ANOVA and Kaplan-Meier test (α = 0.05) were performed for marginal/internal fit, and fatigue behavior data, respectively. PS scanner, CR milling machine, and RC endocrowns resulted in a better marginal fit compared to their counterparts. Still, the PM machine resulted in a better pulpal space fit compared to the CR milling machine. Regardless of the scanner and milling machine, RC endocrowns exhibited superior fatigue behavior than LD ones. LD endocrowns presented margin chipping regardless of the milling machine used. Despite minor differences in terms of fit, the 'IOS' and 'milling machine' factors did not impair the fatigue behavior of endocrowns. Resin-composite restorations resulted in a higher survival rate compared to glass-ceramic ones, independently of the digital devices used in the workflow.

14.
Odontology ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634968

RESUMO

The purpose of this study was to investigate the vertical marginal discrepancy (VMD) and residual excess cement (REC) of cementable and screwmentable monolithic zirconia crowns cemented with different types of cement. Abutments were attached to 40 implant analogues. Crowns were created using computer-aided design/computer-aided manufacturing technology from monolithic zirconia blocks, either with or without a screw access hole (SAC). Crowns created both ways were split into two groups and cemented with resin and zinc polycarboxylate cement under a 5-kg weight. VMD and REC values were evaluated using an X20 zoom stereomicroscope. Data were analysed using two-way ANOVA and the Bonferroni test. According to the two-way ANOVA results, REC measurements differed significantly in the crown design and cement groups. However, whilst VMD values were significantly different in both crown design groups, there was no significant difference in the cement groups. According to the Bonferroni test results, the highest REC (157.241 ± 44.29 µm) and VMD (68.052 ± 16.19 µm) values were found in the crowns without SAC and cemented with zinc polycarboxylate. Screwmentable crowns are more effective than cementable crowns in reducing REC and VMD. Whilst polycarboxylate cement reduces VMD in screwmentable crowns, resin cement is more suitable for cementable crowns.

15.
J Dent Sci ; 19(2): 1105-1115, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618091

RESUMO

Background/purpose: Nowadays, zirconia-based framework has been used for longspan or full-arch fixed dental prostheses (FDPs). This study aimed to evaluate the effect of pontic distribution on marginal and internal gaps of five-unit anterior zirconiabased DPs. Materials and methods: Right maxillary central incisor and second premolar were selected as terminal abutments and three different edentulous conditions with one nonterminal abutment were simulated. Marginal and internal gaps in each zirconia-based samples(n = 10) were examined by computer-aided replica technique. Five regions, including marginal gaps at mesial or distal finishing line, internal gaps at the mesial or distal axial wall, and occlusal surface, were statistically analyzed (α = .05). Results: Most of marginal gaps and internal gaps at axial wall were clinically acceptable, but larger at occlusal surface. For the three experimental groups, clinically accepted percentage with qualified gaps were less than 30%.There were statistical differences at axial wall over pontic side and marginal gaps over non-pontic side between groups (P<0.05). For sum of gaps of all abutments in each group, statistical differences were found at marginal and axial wall (P < 0.05). As for those on terminal and non-terminal abutments, statistical differences were found on second premolar (P < 0.05). Conclusion: Except for occlusal surface, the overall marginal gaps and internal gaps at axial wall of five-unit anterior zirconia-based FDPs with different pontic distribution were clinically acceptable. However, the percentage with qualified gaps were low (<30%). Greater gaps were noted when adjacent pontic existed. Different pontic size and distribution with curvature had an influence on the gaps.

16.
J Dent Sci ; 19(2): 971-977, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618116

RESUMO

Background/purpose: The adaptation and marginal integrity of computer-aided designed and computer-aided manufactured (CAD/CAM) crowns after exposure to thermal aging need to be investigated. The present in-vitro study was designed to investigate the marginal integrity of CAD/CAM fabricated crowns cemented on extracted teeth after thermocycling aging. Materials and methods: Twenty-six newly extracted human premolars were prepared for full-coverage CAD/CAM crowns and were divided into two groups (leucite-reinforced glass-ceramics and lithium disilicate glass-ceramics). Both crowns' groups were cemented using dual curing resin cement. All specimen margins were measured for marginal integrity using an imaging system 24 h post cementation; then after 1, 3, and 5 estimated clinical years (10,000, 30,000, and 50,000 thermocycles). Two-way ANOVA analysis were used to determine whether the mean value difference is significantly different (ɑ = 0.05). Results: The average margin gaps recorded for leucite-reinforced glass-ceramic crowns were: 82.61 µm initial, and 91.02 µm after 5 estimated clinical year). For the lithium disilicate glass-ceramic crowns, the average margin gaps recorded were: 100.01 µm initial, and 120.21 µm after 5 estimated clinical year. During all measuring intervals, the leucite-reinforced glass-ceramic crown group had a lower marginal discrepancy. No statistically significant difference between the two groups was recorded. Conclusion: After being subjected to thermocycling, both CAD/CAM ceramic crowns, exhibited an increase in their marginal discrepancy; the difference was within the accepted clinical range.

17.
Trials ; 25(1): 267, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627819

RESUMO

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Idoso , Pessoa de Meia-Idade , Revestimento de Dentadura , Fluxo de Trabalho , Mandíbula/cirurgia , Satisfação do Paciente , Impressão Tridimensional , Prótese Dentária Fixada por Implante , Ensaios Clínicos Controlados Aleatórios como Assunto
18.
Cureus ; 16(3): e55804, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38586635

RESUMO

STATEMENT OF PROBLEM: New-generation denture base materials are used successfully in denture fabrication; however, the effect of saliva pH change on the color stability of materials is unknown. PURPOSE: The purpose of this in vitro study is to evaluate the color stability of new-generation denture base materials after immersion in artificial saliva with different pH values (3,7,14). MATERIAL AND METHODS: Disc-shaped samples (Ø 10 mm x 2 mm) were prepared from three different denture base materials (1 pre-polymerized polymethylmethacrylate [PMMA], 1 graphene-reinforced PMMA, and heat-cure polymethyl methacrylate resin) (n=10). After polishing, color coordinates were measured using a PCE-CSM 5 colorimeter programmed in the CIE system (L* a* b*). The samples were kept in artificial saliva at different pH values and 37°C for 21 days. At the end of 21 days, color coordinates were measured again. The suitability of the measurements for a normal distribution was examined with the Kolmogro-Smirnov test. Whether color measurements obtained at different pH levels differed according to groups was examined with the Kruskal-Wallis test. The correlation between the CIEDE2000 and CIELab color difference formulas was examined by correlation analysis. RESULTS: The highest color difference occurred in heat-cure samples at pH 3 (p<0.001). The color difference at different pH values was least observed in pre-polymerized PMMA samples. Significant color differences occurred in the graphene-reinforced pre-polymerized PMMA group at pH 7 (p<0.001). CONCLUSIONS: It was observed that color differences occurred in all groups. Dentures made of new-generation CAD/CAM PMMA, which are less exposed to color differences, can be recommended for elderly patients with systemic diseases who are frequently exposed to pH changes in the oral cavity. CLINICAL IMPLICATIONS: Color differences on denture surfaces over time negatively affect aesthetics. Since pH changes cause changes on the prosthesis surface, it may be recommended for these patients to fabricate dentures from new-generation CAD/CAM PMMA resins, which are less deformable.

19.
J Pharm Bioallied Sci ; 16(Suppl 1): S918-S920, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595350

RESUMO

Objectives: This study compares the bacterial susceptibility to three different provisional restorations manufactured with different laboratory techniques, i.e., heat cure, CAD/CAM, and 3D printing. Materials and Methods: Totally, 45 health patients with age group of 30-60 years undergoing complete veneer crown treatment were selected for the study and divided into three groups with 15 samples in each as Group I: the crowns were made from polymethyl methacrylate polymer fabricated by the conventional heat cure method, Group 2: the crowns were made from polymethyl methacrylate fabricated by subtractive manufacturing CAD/CAM method, and Group 3: the crowns were made from oligomers fabricated by additive manufacturing 3D printing. The samples were examined for bacterial adherence at scanning electron microscope. The colony-forming units (CFUs) were calculated, and statistically analyzed. Results: It has been determined that the digitally fabricated provisional restorations prove to be superior in terms of surface topography than to the conventionally fabricated provisional restorations. Conclusion: The study concludes that 3D-printed provisional restorations are more precise with reduced bacterial susceptibility than milled ones.

20.
J Pharm Bioallied Sci ; 16(Suppl 1): S948-S950, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595595

RESUMO

Introduction: Both the population's average life expectancy and the number of patients without teeth are rising. A 2012 epidemiological survey in India found that 30% of the population is edentulous. The rehabilitation process with a set of removable maxillary and mandibular complete dentures is the standard treatment for patients who are edentulous. This study is the first to incorporate and compare a novel approach to a single implant-retained mandibular overdenture with a bar attachment fabricated by CAD-CAM and a casting process on a single implant in the symphysis region. Method: Five maxillary and mandibular completely edentulous patients were enrolled in the study. Results: Significant difference was seen in the conventional laboratory time and CAD-CAM time as P < 0.05. Conclusion: Compared to the conventional casting process, the single implant-supported bar mandibular overdenture (SISBOD) with a novel bar required fewer man hours and was more convenient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...